Cold Room, Freezer & Flower Chiller Cooling Load Calculator UAE
Estimate preliminary heat loads and refrigeration capacity for cold rooms, holding freezers and specialized chillers using room dimensions, product type, incoming product temperature, daily product quantity, target temperature and insulation.
Estimated Cooling Load and Equipment Selection
Preliminary refrigeration capacity and estimated compressor selection. The selected machine count is used to calculate HP per machine.
Compressor Technical Specifications
- Refrigerant: —
- Evaporating Temperature (SST): — °C
- Condensing Temperature (SCT): — °C
- Estimated Displacement Per Machine: — m³/h at 50 Hz
- Estimated Power Per Machine: — kW
- Estimated HP Per Machine: — HP
- Selection Reference: —
| Load Component | Estimated Capacity |
|---|---|
| Walls and ceiling transmission | — kW |
| Floor transmission | — kW |
| Door / infiltration allowance | — kW |
| Product cooling / respiration load | — kW |
| Fans, lights and people loads | — kW |
| Subtotal before design allowance | — kW |
Estimated Load Breakdown
Load Components (kW)
Request a Technical Assessment from Mana Cold Room
Share your room dimensions, product details and target temperatures with our team for a project-specific calculation and equipment selection.
About Cold Room Cooling Load Calculations
A refrigeration load estimate combines heat entering through insulated surfaces, air exchange through doors, product cooling, product respiration and internal heat from fans, lights and handling activities.
Frequently Asked Questions
How does the calculator estimate compressor HP?
The calculator estimates electrical input using an assumed COP, converts that estimated power to HP and divides the result equally by the selected number of machines. It is a preliminary estimate, not a manufacturer's compressor rating.
Can I select 1, 2, 3 or 4 machines?
Yes. Select the required number of machines in the machine parameters. The calculator displays the estimated HP per machine and total HP.
How is incoming product temperature used?
The calculator estimates product cooling energy from incoming product temperature, daily product quantity and target room temperature. For products entering above their indicative freezing point and being cooled below it, an indicative latent freezing-energy allowance is included.
Does UAE ambient temperature affect refrigeration capacity?
Yes. Higher condensing temperatures can reduce compressor capacity and increase power consumption. Verify the actual compressor selection at the design operating conditions.